Date/Time | Action | Notes |
---|---|---|
9:15 | Briefing @ WARG Bay | |
9:45 | Arrival at Flight Test Location | about 5 cm of snow on entire skid pad |
10:15 | Flight Test Card #1 - Efficiency/Endurance, 3 Waypoints | Flight 0 - couple hundred meters. Used blue controller. Took off, LTE dropped out after 5 seconds. Ended up returning to home - first flew up to 100 meters ~ 200 meters away to hit the first waypoint, then the 45 second no-telemetry count down kicked in. Switched to RFDs. Flight 1 - 1.2 km total flight. all fully autonomous through mission planner. Took turns a little hard. When returning, flew over the firefighter zone. Fixed this for the next flyover. |
10:25 | Flight 2 - 1.2 km total flight. same as previous. Did not fly over firefighters. | |
10:45 | Flight 3 - 1.2 km total flight. Had to check battery health immediately following this. Battery failsafed about 10 meters off the ground, tried to land, Nathan took over on the blue TX manually. Had to hit full throttle immediately after taking control just to stop the drone from falling. Batteries visibly sagged very hard and drone had a slightly rough landing (not a free fall, just a slow drop) from about 2 meters. Can be seen in IMG_1496 March 23 - OneDrive (sharepoint.com) | |
10:50 | Flight test card 3 - RTK GPS checks | Took ~ 5-10 minutes. Got a hold. |
11:30 | Debrief | Below |
|
| |
|
|
...
💻 DEBRIEF
Logs: https://uofwaterloo-my.sharepoint.com/:f:/g/personal/uwarg_uwaterloo_ca/EprwSfOtGeZOom-fAK63e0gBZ2c94HDJ8xIIYBWXcJXheg?e=hJEmC2 Connect your OneDrive account
Media Ingest: https://uofwaterloo-my.sharepoint.com/:f:/g/personal/uwarg_uwaterloo_ca/EqjTFLI7eSZHil5CgZ13PYMBk9KPlNMFPESkOseTALivzg?e=tapYW3 Connect your OneDrive account
Tip |
---|
|
Note |
---|
|
...
|
Warning |
---|
|
Action items
Reset the LTE module because current settings made it worse
made a board that switches RFD to LTE
takes PWM input
Do we have GPIO? -@aidan
if so we can just use this to switch transmission
Can we just measure RSSI?
LTE doesn’t report a RSSI.
need a LUA script to say ‘if disconnected' check after 20 sec and if still disconnected, switch over.
This should be ok for comp because control is still connected. ELRS.
...