Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • Vout = 0.8 * (1 + R1/R2)

  • 5V output requires standard resistor values of: R1 = 52.3k, R2 = 10k (recommended from datasheet) this yields around 4.984V

  • alternatively, R1 = 53.6k yields around 5.088V

  • Even better, 10.5K, 2K gives exactly 5V (strange that this was not recommended by the D.S)

  • “The combination of R1 and R2 should be large enough to avoid drawing excessive current from the output, which will cause power loss” - This says nothing about the resistor values being too large so I will go ahead with larger values as it allows for a more accurate 5V rail

  • given this case: 105k and 20k would also be ideal

  • standard resistor values source: https://www.rfcafe.com/references/electrical/resistor-values.htm

Component Calculations

...

https://www.ti.com/lit/an/slva477b/slva477b.pdf?ts=1721655939318&ref_url=https%253A%252F%252Fwww.google.com%252F

...

  • Vin = 20 - 26V

  • Vout = 5V

  • Fs ~ 1MHz

  • Ripple Current estimation: IL = (0.2 to 0.4) * 4A = 0.8 to 1.6

...

image-20240723-140014.pngImage Removed

Others

  • Enable Pin is high between 1.2V and 5V so 3.3V from the AFE IC will be supplied to this pin (filter cap needed??)

  • Soft start Pin: “A soft start process begins when the input voltage rises to 3V and voltage on EN pin is HIGH. In soft start process, a 2.5µA internal current source charges the external capacitor at SS. As the SS capacitor is charged, the voltage at SS rises. The SS voltage clamps the reference voltage of the error amplifier, therefore output voltage rising time follows the SS pin voltage. With the slow ramping up output voltage, the inrush current can be prevented. Minimum external soft-start capacitor 850pF is required, and the corresponding soft-start time is about 200µs.”

    • will be using 10nF cap, was available on the WARG component library (relatively similar value)

  • Schottky Diode:

    • To reduce the losses due to the forward voltage drop and recovery of diode, Schottky diode is recommended to use. The maximum reverse voltage rating of the chosen Schottky diode should be greater than the maximum input voltage, and the current rating should be greater than the maximum load current.

    • Using the SK54A-LTP Diode which is already in the warg component library

    • rated for 40V @ 5A which should be enough for 26Vin and 4A current out

...