I have already set V_FB=0.5V by connecting VSEL_1 and VSEL_2 to VCC
...
Updated (10/3): to compensate for the DCR losses, the voltage aimed to be regulated is changed to 5.1V
In this case, R1/R2=9.2, R2=10kOhms, R1=92kOhms, the library values I found are 10k and 91k.
System Block Diagram
...
Reverse Polarity Protection
...