Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

I have already set V_FB=0.5V by connecting VSEL_1 and VSEL_2 to VCC

...

Updated (10/3): to compensate for the DCR losses, the voltage aimed to be regulated is changed to 5.1V

In this case, R1/R2=9.2, R2=10kOhms, R1=92kOhms, the library values I found are 10k and 91k.

System Block Diagram

...

Reverse Polarity Protection

...