Task 2 Egg/Dropping Idea - Coffee Grounds
Note: Everyone contributing to this doc should have already carefully read through CONOPS, found here: https://www.aerialevolution.ca/wp-content/uploads/2026/09/2027-AEAC-CONOPS-v1.0-2026-09-08.pdf
Specifically, make sure you are familiar with the task two description, and the mark breakdown.
See pages 23-26 of the CONOPS, under section 5.2.4
Big Project | Project | Project Manager |
|---|---|---|
Valkyrie | Comp 2027 | Jackson Barber |
Jackson Barber I can try to write these in within the next week, if you can fill them out yourselves that would be great
Constraints | Written By | Append Date |
|---|---|---|
The gripper must accommodate an egg without cracking it during pickup, transport, or release. | Adam Saari | Sep 30, 2026 |
The gripper must accommodate droppings up to 3 cm in diameter without squishing or deforming them. | Adam Saari | Sep 30, 2026 |
The gripper must be capable of placing the collected sample into a basket or other collection container at the pick-up zone, allowing the sample to be manually unloaded. | Adam Saari | Sep 30, 2026 |
The gripper must maintain its grip on the sample throughout the complete flight from the collection area to the flight-line drop-off zone. (If making multiple trips) | Adam Saari | Sep 30, 2026 |
The gripper must allow at least 4 individual droppings to be collected and returned, with each dropping remaining an individual, unsquished sphere. | Adam Saari | Sep 30, 2026 |
The gripper must support autonomous pickup and release with 0 operator intervention if the team is targeting the autonomous sample-collection points. | Adam Saari | Sep 30, 2026 |
Task Description
Task 2 is split into 2 main mechanical tasks, tagging and sample collection.
Tagging: We will create a custom tracker that can either be attached to the prop animal using a hook and loop fastener, or dropped in a nearby box for less points.
Sample Collection: We will look for and attempt to pick up 3 different kinds of samples
After picking these up we will drop them off in a designated location
Task Progression/Updates
Author: person updating Date:
October 5 Meeting
Prototyping a manually actuated syringe with coffee grinds in a balloon
If this works we can get a vacuum gauge and necessary attachments to measure the vacuum that was used
To Do:
Summarize procedure for building the syringe mechanism and how it will be assembled and sealed
Ping leads to review
Make a BOM
Gabriel Singaraja can put in purchase order for components
Design some different cone shapes to experiment with
Prototype: Syringe-Actuated Particle Jamming Gripper
Build and seal procedure
Fill: Funnel about 1 tbsp of coffee grounds at a time into a balloon. Between scoops, partially inflate it so the grounds settle. Stop when the filled balloon sticks out of the cone by about 1".
Trim the cone neck to about 0.5" with wire cutters. Deburr it so it can't tear the balloon.
Filter: Stuff quilter stuffing into the syringe tip (direct mount) or into the tube end (tubed mount). Without it, grounds get sucked into the syringe and tube.
Seal the balloon to the cone:
Pull the balloon neck through the cone neck and wrap it over the opening.
Tape it, or zip-tie it tight and clip the tail.
Connect, either way
Direct mount (easiest seal): Push a tapered-tip syringe into the cone neck and tape it. Keep the plunger slightly off the end.
Tubed mount: Zip-tie the tube into the balloon neck. Pull the balloon into the cone by the tube and tape the tube to the cone. Attach the syringe with some air left inside.
Operate: Push the plunger in to inflate slightly, press the gripper onto the object, then pull the plunger out to jam.
BOM
Item | Qty | Notes |
|---|---|---|
60 mL syringe, tapered/catheter tip | 6+ | Direct mount. Buy spares. |
60 mL syringe, Luer lock | 4 | Tubed mount. Verify the tube fit before relying on it. |
Soft tubing, ¼" per the lab | ~1 m | Match the tube ID to the syringe tip. |
Balloons | 1 pack | Include spares for tear tests. |
Coffee grounds (dry) | 1 cup | Sand as a comparison fill. |
Quilter stuffing | 1 bag | Filter. |
Zip ties (small) | 1 pack |
|
Tape (duct or similar) | 1 roll |
|
Cones | 6–9 printed | Plus 1–2 plastic funnels as a baseline. |
Plunger lock | 1–2 | Printed clip or a simple stop. |
Tools: wire cutters, scissors, tweezers, calipers | 1 each | Calipers are needed for the fit tolerances. |
*Note: Tubing is not required and the syringe tip can be inserted directly to the cone, tubing offers a different technique. Remove the syringes that aren’t necessary for purchase.