8a. Try with a power supply first, set its output current slew rate to max, then connect the circuit before turning on the power supply.

8b. Plug in battery

Battery Inrush Test (Run #2)

  1. Make sure to put 2 batteries in series, Vin should be around 44V

  2. Probe

    1. Buck Vin at C3

    2. Buck Iin on the power wire between battery and input XT60 connector

    3. Vout at D2

  3. Set eload to 0.1A

  4. Turn on eload

  5. Set oscilloscope to single, trigger on half of buck vin rising edge

  6. Take a screenshot of Vin rising at startup, zoom in on the Vin overshoot behavior

Once you are done please place the oscilloscope screenshots in https://uwarg-docs.atlassian.net/wiki/spaces/EL/pages/2501443590/Validation+Result#Efuses

...