8a. Try with a power supply first, set its output current slew rate to max, then connect the circuit before turning on the power supply.
8b. Plug in battery
Battery Inrush Test (Run #2)
Make sure to put 2 batteries in series, Vin should be around 44V
Probe
Buck Vin at C3
Buck Iin on the power wire between battery and input XT60 connector
Vout at D2
Set eload to 0.1A
Turn on eload
Set oscilloscope to single, trigger on half of buck vin rising edge
Take a screenshot of Vin rising at startup, zoom in on the Vin overshoot behavior
Once you are done please place the oscilloscope screenshots in https://uwarg-docs.atlassian.net/wiki/spaces/EL/pages/2501443590/Validation+Result#Efuses
...