Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 14 Next »

Buck converter:

Start-up testing

  1. Measure R between Vin and GND, Vin and SW, SW and GND, Vout and GND

  2. Measure R of feedback resistors, frequency select resistor

  3. Set up a start up test, 1 probe on SW and 1 probe on Vout. Set up oscilloscope to measure waveforms on SW and Vout and make sure to set trigger to single. Then quickly turn on and off the power supply. Hopefully the waveforms show that buck converter works or explain why it doesn’t work.

Load regulation

Load transient

Vout ripple

Set up: Oscilloscope AC coupled, 1GHz bandwidh

Over current protection

IMG_2047.mov

Efuses

PWM buffer

  • No labels